DavidPoz
Heat Exchanger in Tank

Heat Exchanger in Tank

By David Poz·

For the heat exchanger, we went with a PEX coil — 300 feet of one-inch nominal tubing from Uponor. The interior volume holds about 8.6 gallons of water, which gives us a good amount of thermal mass moving through the coil at any given time.

We debated between PEX and copper. A comparable copper unit (3/4" x 60') cost about the same — roughly $300 — but the PEX gives us five times the length and more surface area for heat transfer. The tradeoff is that copper conducts heat better per unit length, so it's not a clear-cut winner either way.

One downside: the PEX had a strong plastic smell when we first installed it. That took about three weeks to fully dissipate. Not a dealbreaker, but worth knowing if you're building something similar.

With the heat exchanger coiled inside the insulated, lined tank, the storage system is complete. The next phase will be connecting the solar collectors on the roof and running the circulation loop.