Battery Cell Voltage Reference
Find how many cells in series you need for your battery bank across different chemistries.
Lithium Iron Phosphate (LiFePO4)
Nominal Cell Voltage
3.2 V
Extreme Low
2.5 V
Extreme High
3.65 V
Ideal Range
3 – 3.5 V
| Cells in Series | Nominal Pack V | Ideal Low V | Ideal High V | |
|---|---|---|---|---|
| 14S | 44.8 V | 42.0 V | 49.0 V | |
| 15S | 48.0 V | 45.0 V | 52.5 V | |
| 16S | 51.2 V | 48.0 V | 56.0 V | Recommended |
| 17S | 54.4 V | 51.0 V | 59.5 V | |
| 18S | 57.6 V | 54.0 V | 63.0 V |
Voltage Range Visualization (48V Target)
How to read this table
Each row shows a series configuration — the number of cells wired in series to form a battery pack.
Nominal Pack V is the cell's nominal voltage multiplied by the series count. This is the "resting" voltage you'll typically see.
Ideal Low / High define the voltage window for normal daily cycling. Staying within this range maximizes battery lifespan.
The Recommended row is the most common series count for a 48V system with that chemistry. Most inverters and charge controllers are designed around this configuration.
The visualization bar shows how each configuration's voltage range relates to a 48V target (amber line). The dot marks the nominal voltage.